ACT-2 A/C valve tester

ACT-2 tester is used to check the correct operation of the following types of A/C compressors:

– compressor with electromagnetic clutch – check the condition of the electromagnetic clutch,

– compressor with clutchless drive – check the operation of the electromagnetic valve controlling the compressor output.

Dostępność:

mag

EAN:

5906236591174

Numer części:

ACT-2

341,75

420,35

brutto

Description

ACT-2 tester is used to check the correct operation of the following types of A/C compressors:

– Compressor with electromagnetic clutch – check the condition of the electromagnetic clutch,

– Compressor with clutchless drive – check the operation of the solenoid valve that controls the compressor output.

Attention! The tester does not support solenoid valves with a built-in safety diode (valves used in Mercedes cars, among others). Using a tester for this type of valve may damage the valve or the tester.

The tester can be used both on the air conditioning test bench and by checking the compressor in the car.

Technical parameters of the tester:

Supply voltageconstant, range 12 … 15V
Current consumption70 mA (current drawn by the tester without load)
Control signal generator
Frequency range20Hz – 1000Hz
Frequency control accuracy1Hz
Amplitude of the output signalFrom 0V to the supply voltage
Type of controlGround controlled output and supply voltage controlled output
Coefficient adjustment range0% … 100%
Coefficient adjustment accuracy0.1%
Measurement of the control signal
Measured frequency range20Hz – 1000Hz
Input signal amplitudefrom 0V to supply voltage
Switching voltage threshold2.5V
Security
VoltageExceeding the supply voltage (above 18V)
CurrentExceeding the allowable current of 6.3A (fuse)
and short circuit protection

 

ACT-2 kit contents:

 

ACT-2 device

Measurement and control cable (15pin plug)

6A spare fuse

15V power supply

 

You can download the manual for the device by clicking HERE

Additional information

Weight2 kg

Inpost

DHL EU

Fedex World

What is the ACT-2 tester for?

The ACT-2 tester is used to check the correct operation of solenoid valves used in passenger cars to regulate the flow of air conditioning coolant.

 

Attention! The ACT-2 tester is not suitable for checking solenoid valves with a protective diode or other elements protecting against overvoltage.

 

What power supply does the ACT-2 tester require?

The tester tolerates supply voltages in the range of 12 … 15V. The voltage source should have a current efficiency of at least 4A. The kit includes stabilized power supply intended to power the tester.

 

Is it possible to update on-line?

It is not possible to update the ACT-2 tester online.

 

What signal frequency range does the ACT-2 generate?

The generated frequency range is: 20Hz … 1000Hz. The device allows you to set the frequency with an resolution of 1Hz.

 

What range of the signal duty cycle can be set?

The duty cycle can be adjusted in the range of 0% … 100% with an resolution of 0.1%.

 

Are the original connectors adapted to the connection of valves included in the set?

The valves are connected to the tester by means of cables terminated with universal terminals. The set does not include the original connectors.