DM-1 is a 1-channel automotive oscilloscope/diagnoscope that allows diagnostics of electronic and electrical equipment in vehicles of various makes and models. Thanks to its compact size and rugged design, the device works well in harsh workshop environments. The DM-1 is easy to use, and the built-in rechargeable battery provides many hours of operation.

 

To download the program for DM-1 click
HERE

Availability:
Available
Categories: ,

539,75 VAT 0%
663,89 VAT 23%

The oscilloscope’s input circuit accepts a wide range of voltages and is protected by surge protection. Thus, with the DM-1 oscilloscope, we can diagnose both low-voltage sensor circuits and ignition system control components.

The diagnoscope function allows you to select oscilloscope settings according to the selected component. After selecting a component from the list, we gain initial settings for time base and gain, as well as an example waveform.

The device works with a PC program, allowing you to view and record waveforms on your computer. In addition, the software package includes the Common Rai pressure testing program.

Technical parameters of the device:

  • ADC: 8 bit, 32 Msps
  • Input bandwidth: 1 MHz (-3 dB)
  • Input impedance: 1 MΩ, 20 pF
  • Display: 128 x 64, backlit, monochrome
  • Voltage measurement range: -80V to 80V
  • Time base: 1.25 us – 1 h per plot
  • Gain: 5 mV – 20V per division
  • Number of memory cells: 7
  • Supply voltage: 12V 0.5A
  • Rechargeable battery: NiMH 6.2V 2000mAh
  • Maximum operating time (battery): 10 h
  • Operating temperature: 0 – 50°C
  • Available languages: Polish, English
  • Communication: RS-232
  • Dimensions: 238 x 116 x 81 mm
  • Weight: 650 g
  • EAN: 5906236591495

Kit contents:

  • DM-1 device
  • Measurement cable 0.5 m with crocodiles
  • Power supply 12V 1,5A with 1,8 m cable
  • RS-232 cable 1.5 m

 

 

Technical data of the diagnoscope:

Analog-to-digital converter: 32 MHz
Input bandwidth: 1 MHz (-3dB for 1V/dz)
Input impedance: 1 MΩ/20pF
Input voltage range: -100V to 100V peak (without probe x10)
Input signal type: AC, DC, GND
Measurement resolution: 8 bit
Linearity: +/- 1bit
Display: LCD backlit monochrome, 64 x 128 pixels
DC voltage measurement range: -80V to 80V (without probe x10)
Inter-peak voltage measurement range: 0 to 160V (without probe x10)
Time basics: 1.25us; 2.5us; 5us; 10us; 20us; 50us; 100us;200us; 500us; 1ms; 2ms; 5ms; 10ms; 20ms;50ms;
100ms; 200ms; 500ms; 1s; 2s; 5s; 10s;20s; 30s; 1min; 2min; 5min; 10min; 20min;30min; 1h per plot.
Gain (without probe x10): 5mV; 10mV; 20mV; 50mV; 0.1V; 0.2V; 0.4V1V; 2V; 4V; 8V; 20V per plot.
Probe calibration signal output x10: 1kHz/ approx. 5Vpp, 50% gain (optional)
Number of memory cells: 7
Supply voltage: 11VDC to 15VDC 500mA
Batteries: Type AA NiMH minimum 1800 mAh – 5 pcs.
Maximum battery charging current: 200 mA
Maximum battery life: 10 h
Operating temperature: 0 – 50 degrees C
Sizes: 80x200x120mm
Weight: 450g (without batteries)

The DM-1 Diagnoscope can also serve as a PC attachment turning it into an oscilloscope. The program that performs this function under the promotion is provided free of charge.

 

DM1 - chart

DM1 – chart

 

The price of the diagnoscope also includes the COMMON RAIL PRESSURE TESTER program.

It allows you to measure the pressure on the COMMON RAIL strip and is designed for sensors with different pressure ranges (it is possible to enter the maximum pressure of the sensor).

In addition, when the option is switched, the program measures the signal fill factor (PWM) on the pressure control valves.

 

DM1

DM1

 

Warranty: 24 months
Shipping time: In stock!

Additional information

Weight 2 kg
approximate gross weight
InPost PL, DHL EU, Fedex World
Files for logged in buyers

To be able to download files you need to log in.

Publicly available files Unfortunately, there are no downloads available.

DM-1 – FAQ

 

I lost my software CD. How can I get the software?

The software for the device can be downloaded after prior registration and logging in to our website: https://dte.com.pl/en/my-data/

 

My computer does not have a serial port, how do I connect the device to my computer?

In the case of computers with USB ports, you can use the USB -> Serial Port (COM) adapter. It is good to choose a good quality product, e.g. based on the FT232RL chip. If you have an older software, please download the current version.

 

The original power supply has been damaged. Which power supply should I use?

In the event of a defect during the warranty period, please contact our service. The device requires a stabilized 12V power supply with a 5.5 / 2.5mm connector (positive tip, negative sleeve).

 

I have an older DM-1 device. Is it possible to replace the battery or repair the device?

We offer both the possibility of replacing the battery and the possibility of repairing or calibrating older devices. We invite you to contact our service.